Rabu, 15 Juni 2011

ANESTHESIA APPARATUR FO - 20 S

Anesthesia Apparatus FO-20S
Superb functional efficiency in a compact body.
Simple and cost-effective.
Offers great utility in all situations.


 
 Reliable security
  • N2O and O2 metering is jointly controlled by a special mechanically interlocking gear system, that ensures patient safety by controlling the minimum oxygen concentration so that it never goes below 30% (±3 Vol. %, when O2 flow is over 1 L/min.). (PAT. 1737472)
  • If O2 supply pressure drops below 240 to 260 kPa, whistle sounds.
  • If O2 supply pressure falls below 100kPa (approx. 1kgf/cm2), the N2O flow into the circuit is automatically suspended for assurance of patient safety.
■ Easy operation
  • Convenient, easy disposal of surplus gas
  • Easy-to-handle canister
  • One-touch oxygen flushing
■ Compact and Customizable.
  • FO-20S can be carried conveniently anywhere by means of the carrying handle.
  • An Anesthetic ventilator (such as Acoma PRO-V mkII,ARF-900II & ACE-3000) can be installed within the mobile stand.
  • A built-in drawer on small mobile stand provides readily available storage space for various instruments, accessories, and other small items.(option)
  • Large castors for smooth, easy unit mobility combined with firm locking.
  • Rail type mount for 2 Vaporizers is optionally available for stand C.

■ Small mobile stands
Select from the 3 types A/B/C to satisfy every need.

110cm

125cm

137.6cm

 A 
 Main unit + Stand type A
 A 
Designed to be as compact as possible
 B 
 Main unit + Stand type B
 A 
Maintaining the compact form of the A type with a monitor base
 C 
 Main unit + Stand type C
 C 
Can be installed with 2 vaporizer units. Position of the respiratory apparatus is adjustable.

■ Ventilator supporting FO-20S.
Select from two options: Electric drive method and gas drive method

An Anesthetic Ventilator Developed for Fast, Operational Ease

Ventilation methodVolum Preset., Time Cycling
Ventilation modeContoller, Assistor/Controller
Approval No.20200BZZ00718000

Gas-driven Anesthetic Ventilator with electronic control. Versatile enough to meet the requirements of neonatal through to adult applications

Ventilation methodVolume preset and time cycling mode
Pressure preset and time cycling mode
Respiration methodTime-cycling mode, pressure limit mode, CMV, IMV, assisted respiration, CPAP (when installed with a respiration valve unit with PEEP)
Approval No.20500BZZ00040000